Blackline Gas Detection Sensors
GAS DETECTION SOLUTION
Tailor your G7 wearables and G7 EXO area monitors with a unique modular sensor cartridge design, catering to your specific gas detection and safety requirements. With easy-to-swap modular sensor cartridges, users can swiftly replace failed or expired sensors, ensuring minimal downtime and maximum efficiency.
Transitioning from single-gas to multi-gas monitoring is effortless—all it takes is a sensor cartridge change.
Enjoy peace of mind with our sensors and pumps, backed by a lifetime warranty with an active service plan. Compatible with the G7 Dock, all cartridges enable straightforward bump tests and calibrations, streamlining maintenance procedures.
For enhanced safety in confined spaces, devices equipped with pump cartridges offer comprehensive workflows for entry and leak checks. Plus, benefit from automated mapping of confined space entries, gas exposures, usage, and alerts, providing unparalleled insight and control over your safety operations.
Gas
Detection
Man Down
Alerting
Blackline
Live Portal
24/7 Emergency
Monitoring
For environments with specific gas hazards, the Single-gas diffusion cartridge provides targeted gas detection, seamlessly compatible with G7 wearables.
The Multi-gas diffusion cartridge, compatible with G7 and G7 EXO, accommodates up to four sensors, monitoring for up to five gases, including dual-toxic COSH sensors.
Additionally, the Multi-gas pump cartridge, featuring an internal pump, is ideal for confined space entry and leak check applications. Users can customize their G7 functionality through the Blackline Live portal, ensuring adaptability to various scenarios for comprehensive safety monitoring.
- Single-gas diffusion cartridge – Our single-gas diffusion cartridge supports you with a choice of over 20 sensors.
- Multi-gas diffusion cartridge – Accommodates 2-4 sensors and monitors up to 5 gases with a dual-toxic COSH sensor. This cartridge supports all sensors in our portfolio (G7 and G7 EXO compatible).
- Multi-gas pump cartridge – Can monitor up to 5 gases (with a COSH sensor) and features an internal pump. Suitable for confined space entry and leak checks, users can control the pump on-the-go with configurable modes, adaptable through the Blackline Live portal.
Gas | Sensor type | Sensor model | Range | Resolution |
Ammonia (NH3) | Electrochemical | Citytech, Sensoric NH3 3E 100 SE | 0–100 ppm | 0.1 ppm |
High-range ammonia (NH3) | Electrochemical | Sensoric NH3 E3 500 SE | 0–500 ppm | 1 ppm |
Carbon monoxide (CO) | Electrochemical | Citytech, 4CF+ CiTiceL | 0–500 ppm | 1 ppm |
High-range carbon monoxide (CO) | Electrochemical | Citytech 4CM | 0–2000 ppm | 5 ppm |
Hydrogen resistant carbon monoxide (CO-H) | Electrochemical | Citytech 2CF3 | 0–500 ppm | 1 ppm |
Carbon dioxide (CO2) | NDIR | Gas Sensing Solutions, MinIR | 0–50,000 ppm | 50 ppm |
Chlorine (Cl2) | Electrochemical | Citytech, Sensoric Cl2 3E 50 | 0–20 ppm | 0.1 ppm |
Chlorine dioxide (ClO2) | Electrochemical | Sensoric ClO2 3E 1 O | 0–2 ppm | 0.01 ppm |
COSH | Electrochemical | Citytech, 4COSH Dual Gas CO/ H2S Sensor | 0–500 ppm CO, 0–100 ppm H2S | 1 ppm CO, 0.1 ppm H2S |
Hydrogen cyanide (HCN) | Electrochemical | Sensoric HCN 3E 30 F | 0–30 ppm | 0.1 ppm |
Hydrogen sulfide (H2S) | Electrochemical | City Technology, 4HS+ Hydrogen Sulfide CiTiceL | 0–100 ppm | 0.1 ppm |
High-range hydrogen sulfide (H2S) | Electrochemical | City Technology, 4HS+ Hydrogen Sulfide CiTiceL | 0-500 ppm | 0.5 ppm |
LEL-MPSTM See Blackline’s LEL-MPS datasheet for more information | Molecular property spectrometerTM | Nevada Nano, LEL MPSTM | 0–100% LEL | 0.1% LEL |
LEL-infrared (LEL-IR) | NDIR | MIPEX, 02-X-X-X.1 | 0–100% LEL | 1% LEL |
Nitrogen dioxide (NO2) | Electrochemical | City Technology, 4ND | 0–50 ppm | 0.1 ppm |
Oxygen (O2) | Pumped electrochemical | City Technology, 4OxLL Longlife Oxygen CiTiceL | 0–25% vol | 0.1% vol |
Ozone (O3) | Electrochemical | Sensoric O3 3E 1 | 0–1 ppm | 0.01 ppm |
Photoionization (PID) ppm | PID | Ion Science, MiniPID 2 | 0–4,000 ppm* | Dynamic resolution*, |
0.1 ppm | ||||
Sulfur dioxide (SO2) | Electrochemical | City Technology, 4S Rev. 2 Sulfur Dioxide CiTiceL | 0–100 ppm | 0.1 ppm |
- Blackline offers cartridge replacements as a service plan with new cartridges shipped to locations.
At the heart of lone worker safety, the Monitoring Support Centre serves as a critical hub, providing indispensable 24/7 support to enhance security and responsiveness in the face of potential risks.
Direct Safety has meticulously crafted emergency response protocols tailored for industries with lone workers, ensuring the safety and well-being of individuals operating in isolated environments where potential threats or emergencies can arise at any time, day or night.
Leveraging cutting-edge technology and real-time monitoring solutions to fortify the safety net for lone workers. The company’s expertly trained monitoring staff ensures that all alerts are promptly and efficiently responded to, relieving the burden on your internal resources. This process includes swift escalation to local emergency services, facilitated by the sharing of vital information such as real-time location data, alert details, and any additional insights obtained through the two-way communication capabilities inherent in our devices and portal.
The management of alerts occurs seamlessly through Direct Safety’s cloud-hosted web portal, adhering to the highest industry standards with an impressive track record of over 99.5% uptime. This ensures continuous online access 24/7 from any location worldwide. In essence, Direct Safety’s comprehensive approach integrates advanced technology, expert monitoring, and efficient emergency response, providing lone workers with a robust safety framework that is both proactive and reliable.